<?xml version="1.0" encoding="UTF-8" ?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T12:14:08Z</responseDate><request verb="GetRecord" metadataPrefix="oai_dc" identifier="oai:10442/8818">https://phdtheses.ekt.gr/eadd_oai/request</request><GetRecord><record><header><identifier>oai:10442/8818</identifier><datestamp>2024-07-09T13:55:54Z</datestamp><setSpec>hdl_10442_2</setSpec></header><metadata><oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><dc:description xmlns:lang="el">ΣΤΗΝ ΠΑΡΟΥΣΑ ΔΙΑΤΡΙΒΗ ΕΓΙΝΕ Η ΘΕΩΡΗΤΙΚΗ ΚΑΙ ΠΕΙΡΑΜΑΤΙΚΗ ΔΙΕΡΕΥΝΗΣΗ ΤΟΥ ΘΕΜΑΤΟΣ ΤΗΣ ΑΞΙΟΠΟΙΗΣΗΣ ΤΗΣ ΗΛΙΑΚΗΣ ΕΝΕΡΓΕΙΑΣ ΣΤΗ ΠΑΡΑΓΩΓΗ ΨΥΧΟΥΣ. ΤΟ ΘΕΜΑ ΕΞΕΙΔΙΚΕΥΘΗΚΕ ΣΤΗ ΧΡΗΣΗ ΤΗΣ ΜΕΘΟΔΟΥ ΘΕΡΜΟΣΥΜΠΙΕΣΕΩΣ ΩΣ ΤΗΣ ΑΝΤΙΣΤΟΙΧΟΥ  ΔΙΕΡΓΑΣΙΑΣ ΤΟΥ ΚΥΚΛΟΥ ΠΑΡΑΓΩΓΗΣ ΨΥΧΟΥΣ. ΤΟ ΠΕΙΡΑΜΑΤΙΚΟ ΜΕΡΟΣ ΠΕΡΙΕΛΑΒΕ ΤΟΝ  ΣΧΕΔΙΑΣΜΟ ΚΑΙ ΚΑΤΑΣΚΕΥΗ ΜΙΑΣ ΜΕΓΑΛΗΣ ΚΛΙΜΑΚΟΣ ΗΛΙΑΚΗΣ ΕΓΚΑΤΑΣΤΑΣΗΣ ΨΥΞΕΩΣ ΜΕ  ΑΠΟΡΡΟΦΗΣΗ ΚΑΙ ΧΡΗΣΗ ΔΕΞΑΜΕΝΩΝ ΘΕΡΜΟΤΗΤΟΣ, ΚΑΘΩΣ ΚΑΙ ΤΟΝ ΣΧΕΔΙΑΣΜΟ ΚΑΙ  ΚΑΤΑΣΚΕΥΗ ΔΥΟ ΜΟΝΑΔΩΝ ΨΥΞΕΩΣ ΜΕ ΘΕΡΜΟΣΥΜΠΙΕΣΗ, ΔΥΝΑΜΙΚΟΤΗΤΟΣ 0,75 ΚΑΙ 2  ΨΥΚΤΙΚΩΝ ΤΟΝΝΩΝ ΑΝΤΙΣΤΟΙΧΑ. Η ΗΛΙΑΚΗ ΕΓΚΑΤΑΣΤΑΣΗ ΑΠΟΡΡΟΦΗΣΕΩΣ ΑΠΟΤΕΛΕΙΤΟ ΑΠΟ  613 M^2 ΣΥΛΛΕΚΤΩΝ ΣΩΛΗΝΩΝ ΚΕΝΟΥ, Η ΔΕ ΑΝΗΓΜΕΝΗ ΩΣ ΠΡΟΣ ΤΟ ΨΥΚΤΙΚΟ ΑΠΟΤΕΛΕΣΜΑ  ΣΥΛΛΕΚΤΙΚΗ ΕΠΙΦΑΝΕΙΑ ΗΤΑΝ 11,8 M^2/RT. Η ΕΓΚΑΤΑΣΤΑΣΗ ΑΥΤΗ ΑΠΟΔΙΔΕΙ 102.000  ΘΕΡΜΙΚΕΣ KWH ΚΑΤΑ ΤΟ ΧΕΙΜΩΝΑ ΚΑΙ 185.000ΘΕΡΜΙΚΕΣ KWH ΚΑΤΑ ΤΟ ΚΑΛΟΚΑΙΡΙ. ΑΠΟ  ΤΑ ΑΠΟΤΕΛΕΣΜΑΤΑ ΤΗΣ ΠΕΙΡΑΜΑΤΙΚΗΣ ΔΙΕΡΕΥΝΗΣΕΩΣ ΔΙΑΠΙΣΤΩΘΗΚΕ ΟΤΙ: Ι) Η ΑΠΟΔΟΣΗ  ΜΙΑΣ ΗΛΙΑΚΗΣ ΕΓΚΑΤΑΣΤΑΣΕΩΣ ΨΥΞΕΩΣ ΕΞΑΡΤΑΤΑΙ ΑΠΟ ΤΙΣ ΘΕΡΜΙΚΕΣ ΑΠΩΛΕΙΕΣ ΤΩΝ  ΔΕΞΑΜΕΝΩΝ, ΑΠΟ ΤΗΝ ΜΕΙΩΣΗ ΤΗΣ ΘΕΡΜΟΚΡΑΣΙΑΣ ΛΕΙΤΟΥΡΓΙΑΣ ΤΟΥ ΨΥΚΤΗ ΛΟΓΩ ΤΗΣ   ΘΕΡΜΙΚΗΣ ΑΔΡΑΝΕΙΑΣ ΤΩΝ ΔΕΞΑΜΕΝΩΝ ΚΑΙ ΑΠΟ ΤΗ ΧΡΟΝΙΚΗ ΥΣΤΕΡΗΣΗ ΤΗΣ   ΜΕΓΙΣΤΟΠΟΙΗΣΕΩΣ ΤΗΣ ΑΠΟΔΟΣΕΩΣ ΤΟΥ ΗΛΙΑΚΟΥ ΠΕΔΙΟΥ ΕΝΑΝΤΙ ΤΗΣ ΜΕΓΙΣΤΟΠΟΙΗΣΕΩΣ  ΤΗΣ ΑΠΟΔΟΣΕΩΣ ΤΩΝ ΨΥΚΤΩΝ. ΙΙ) Ο ΒΑΘΜΟΣ ΑΠΟΔΟΣΕΩΣ ΜΙΑΣ ΗΛΙΑΚΗΣ ΕΓΚΑΤΑΣΤΑΣΕΩΣ   ΨΥΞΕΩΣ ΜΕ ΘΕΡΜΟΣΥΜΠΙΕΣΗ ΑΚΟΛΟΥΘΕΙ ΜΙΑ ΧΑΡΑΚΤΗΡΙΣΤΙΚΗ ΚΑΜΠΥΛΗ ΩΣ ΣΥΝΑΡΤΗΣΗ  ΤΟΥ ΛΟΓΟΥ ΣΥΜΠΙΕΣΕΩΣ ΤΟΥ ΕΞΩΣΤΗΡΑ, Η ΟΠΟΙΑ ΠΑΡΟΥΣΙΑΖΕΙ ΜΕΓΙΣΤΟ ΣΤΙΣ ΣΥΝΘΗΚΕΣ   ΚΑΝΟΝΙΚΗΣ ΛΕΙΤΟΥΡΓΙΑΣ ΣΧΕΔΙΑΣΜΟΥ ΤΟΥ.</dc:description><dc:description xmlns:lang="en">A THEORETICAL AND EXPERIMENTAL INVESTIGATION WAS PERFORMED IN RELATION TO THE  USE OF SOLAR ENERGY FOR COOLING PRODUCTION. EMPHASIS WAS GIVEN ON THE POSSIBILITY OF USING THE THERMAL COMPRESSION METHOD IN THE OPERATION OF THE COOLING CYCLE. THE EXPERIMENTAL WORK COVERED THE DESIGN AND CONSTRUCTION OF A   LARGE SCALE ABSORPTION COOLING SOLAR INSTALLATION WITH VARIOUS CAPACITIES OF   STORAGE TANKS, AS WELL AS THE DESIGN AND CONSTRUCTION OF TWO THERMAL   COMPRESSION COOLING UNITS OF 0.75 AND 2RT CAPACITIES. THE ABSORPTION COOLING   SOLAR INSTALLATIONCONSISTED OF 613 M OF VACUUM TUBE COLLECTORS, WHILE THE   COLLECTORS SURFACE USED PER COOLING CAPACITY WAS AT THE MINIMIZED LEVEL OF   11.8 M/RT. THIS INSTALLATION GIVES AN AVERAGE OUTPUT OF 102,000 THERMAL KWH   DURING WINTER PERIOD AND 185,000 THERMAL KWH DURING SUMMER PERIOD. THE  EXAMINATION OF THE RESULTS OF THE EXPERIMENTAL INVESTIGATION PROVED THAT: I)  THE PERFORMANCE OF A SOLAR COOLING INSTALLATION DEPENDS ON THE RATE OF THE   HEAT LOSES FROM THE STORAGE TANKS, THE DROP OF THE LEVEL OF COOLING PRODUCTION  DUE TO THE TANKS THERMAL INERTIAAND THE TIME DELAY BETWEEN THE PEAK OF THE  SOLAR EFFICIENCY AND THE PEAK OF THE CHILLER'S MAXIMUM OUTPUT. II) THE  EFFICIENCY OF A SOLAR THERMAL COMPRESSIONCOOLING INSTALLATION FOLLOWS A  CHARACTERISTIC CURVE WHICH IS A FUNCTION OF THE EJECTORS COMPRESSION RATIO. THIS CURVE HAS A PEAK VALUE AT THE POINT OF THE EJECTORS NORMAL DESIGN  CONDITIONS.</dc:description><dc:title xmlns:lang="el">Η ΑΞΙΟΠΟΙΗΣΗ ΤΗΣ ΗΛΙΑΚΗΣ ΕΝΕΡΓΕΙΑΣ ΣΤΗΝ ΨΥΞΗ ΚΤΙΡΙΩΝ</dc:title><dc:title xmlns:lang="en">THE UTILIZATION OF SOLAR ENERGY IN THE COOLING OF BUILDINGS</dc:title><dc:creator xmlns:lang="en">Korres, Christos</dc:creator><dc:creator xmlns:lang="el">Κορρές, Χρήστος</dc:creator><dc:date>1995</dc:date><dc:language>gre</dc:language><dc:subject xmlns:lang="en">Cooling</dc:subject><dc:subject xmlns:lang="en">Heat storage</dc:subject><dc:subject xmlns:lang="en">JET COMPRESSOR</dc:subject><dc:subject xmlns:lang="en">Solar energy</dc:subject><dc:subject xmlns:lang="en">VAPOR THERMAL COMPRESSION</dc:subject><dc:subject xmlns:lang="el">Αποθήκευση θερμότητας</dc:subject><dc:subject xmlns:lang="el">ΕΞΩΣΤΗΡΑΣ</dc:subject><dc:subject xmlns:lang="el">Ηλιακή ενέργεια</dc:subject><dc:subject xmlns:lang="el">Θερμοδυναμική</dc:subject><dc:subject xmlns:lang="el">ΘΕΡΜΟΣΥΜΠΙΕΣΗ</dc:subject><dc:subject xmlns:lang="el">Ψύξη</dc:subject><dc:publisher xmlns:lang="el">Εθνικό Μετσόβιο Πολυτεχνείο (ΕΜΠ)</dc:publisher><dc:publisher xmlns:lang="en">National Technical University of Athens (NTUA)</dc:publisher><dc:subject xmlns:lang="en">Engineering and Technology</dc:subject><dc:subject xmlns:lang="en">Chemical Engineering</dc:subject><dc:subject xmlns:lang="el">Επιστήμες Μηχανικού και Τεχνολογία</dc:subject><dc:subject xmlns:lang="el">Επιστήμη Χημικού Μηχανικού</dc:subject><dc:fathernamelatin>J.</dc:fathernamelatin><dc:identifier>10.12681/eadd/8818</dc:identifier><dc:identifier>http://hdl.handle.net/10442/hedi/8818</dc:identifier><dc:type>PhD Thesis</dc:type></oai_dc:dc></metadata></record></GetRecord></OAI-PMH>