<?xml version="1.0" encoding="UTF-8" ?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T12:23:52Z</responseDate><request metadataPrefix="oai_dc" verb="GetRecord" identifier="oai:10442/10509">https://phdtheses.ekt.gr/eadd_oai/request</request><GetRecord><record><header><identifier>oai:10442/10509</identifier><datestamp>2024-07-11T09:53:19Z</datestamp><setSpec>hdl_10442_2</setSpec></header><metadata><oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><dc:description xmlns:lang="el">ΣΚΟΠΟΣ ΤΗΣ ΜΕΛΕΤΗΣ ΗΤΑΝ Η ΣΥΓΚΡΙΣΗ ΜΕΤΑΞΥ ΤΟΥ ΣΥΜΒΑΤΙΚΟΥ ΜΗΧΑΝΙΚΟΥ ΑΕΡΙΣΜΟΥ ΚΑΙΤΟΥ ΑΕΡΙΣΜΟΥ ΥΨΗΛΗΣ ΣΥΧΝΟΤΗΤΑΣ ΜΕ ΕΚΤΟΞΕΥΣΗ , ΟΣΟΝ ΑΦΟΡΑ ΤΙΣ   ΑΙΜΟΔΥΝΑΜΙΚΕΣ ΚΑΙ ΑΝΑΠΝΕΥΣΤΙΚΕΣ ΠΑΡΑΜΕΤΡΟΥΣ , ΣΤΗΝ ΟΞΕΙΑ ΥΠΟΞΑΙΜΙΚΗ   ΑΝΑΠΝΕΥΣΤΙΚΗ ΑΝΕΠΑΡΚΕΙΑ.ΤΟ ΠΕΙΡΑΜΑΤΙΚΟ ΠΡΟΤΥΠΟ   ΠΟΥ ΕΠΙΛΕΧΘΗΚΕ ΗΤΑΝ ΤΟ ΜΗ  ΚΑΡΔΙΟΓΕΝΕΣ ΠΝΕΥΜΟΝΙΚΟ ΟΙΔΗΜΑ ΜΕΤΑ ΑΠΟ ΕΓΧΥΣΗ ΕΛΑΙΚΟΥ ΟΞΕΩΣ ΣΤΗΝ ΠΝΕΥΜΟΝΙΚΗ ΑΡΤΗΡΙΑ ΣΕ 12 ΣΚΥΛΟΥΣ ΣΩΜΑΤΙΚΟΥ ΒΑΡΟΥΣ 12 -18 KGR.ΜΕΤΑ ΤΗ ΣΤΑΘΕΡΟΠΟΙΗΣΗ ΤΟΥ ΠΕΙΡΑΜΑΤΟΖΩΟΥ ΣΕ ΣΥΜΒΑΤΙΚΟ ΜΗΧΑΝΙΚΟ ΑΕΡΙΣΜΟ (ΠΛΗΡΩΣ ΕΛΕΓΧΟΜΕΝΟΣ ΑΕΡΙΣΜΟΣ ΟΓΚ  ΟΥ ΣΤΑΘΕΡΗΣ ΡΟΗΣ ) , ΠΡΑΓΜΑΤΟΠΟΙΗΘΗΚΑΝ ΟΙ ΜΕΤΡΗΣΕΙΣ ΤΩΝ ΒΑΣΙΚΩΝ   ΑΝΑΠΝΕΥΣΤΙΚΩΝ ΚΑΙ ΑΙΜΟΔΥΝΑΜΙΚΩΝ ΠΑΡΑΜΕΤΡΩΝ ΚΑΙ ΑΚΟΛΟΥΘΗΣΕ Η ΠΡΟΚΛΗΣΗ ΤΗΣ   ΒΛΑΒΗΣ.ΟΙ ΠΝΕΥΜΟΝΙΚΗ ΒΛΑΒΗ ΜΕΤΑ ΑΠΟ ΕΓΧΥΣΗ ΕΛΑΙΚΟΥ ΟΞΕΩΣ ΘΕΩΡΟΥΝΤΑΝ   ΙΚΑΝΟΠΟΙΗΤΗΚΗ , ΟΤΑΝ Ο ΔΔΕΙΚΤΗΣ ΟΞΥΓΟΝΩΣΗΣ (PAO2/F  IO2) ΕΠΕΦΤΕ ΚΑΤΩ ΑΠΟ ΤΟ 150 .ΜΕΤΑ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ ΤΗΣ ΒΛΑΒΗΣ Ο ΣΥΜΒΑΤΙΚΟΣ ΜΗΧΑΝΙΚΟΣ ΑΕΡΙΣΜΟΣ   ΕΝΑΛΛΑΧΘΗΚΕ ΚΑΤΑ ΤΥΧΑΙΟ ΤΡΟΠΟ ΜΕ ΑΕΡΙΣΜΟ ΥΨΗΛΗΣ ΣΥΧΝΟΤΗΤΑΣ ΜΕ ΕΚΤΟΞΕΥΣΗ(JET) ΣΕ ΣΥΧΝΟΤΗΤΕΣ 60 , 120 ΚΑΙ 240 ΑΝ./MIN ΣΕ PEEP=0 (ZEEP) ΚΑΙ PEEP=10 CMH2O , ΠΡΟΣΕΧΟ  ΝΤΑΣ ΩΣΤΕ Η PCO2 ΝΑ ΔΙΑΤΗΡΕΙΤΑΙ ΜΕΤΑΞΥ 38 ΚΑΙ 42 MM HG ΣΕ   ΟΛΕΣ ΤΗΣ ΦΑΣΕΙΣ ΤΟΥ ΠΕΙΡΑΜΑΤΟΣ .ΣΕ ΚΑΘΕ ΣΤΑΔΙΟ ΕΠΑΝΑΛΗΦΘΗΚΑΝ ΟΙ ΜΕΤΡΗΣΕΙΣ   ΤΩΝ ΑΝΑΠΝΕΥΣΤΙΚΩΝ ΚΑΙ ΑΙΜΟΔΥΝΑΜΙΚΩΝ ΠΑΡΑΜΕΤΡΩΝ .ΟΙ ΑΝΑΠΝΕΥΣΤΙΚΕΣ ΚΑΙ   ΑΙΜΟΔΥΝΑΜΙΚΕΣΠΑΡΑΜΕΤΡΟΙ ΣΤΙΣ ΔΙΑΦΟΡΕΣ ΣΥΧΝΟΤΗΤΕΣ ΤΟΥ   HFJV ΣΥΓΚΡΙΘΗΚΑΝ ΜΕ   ΕΚΕΙΝΕΣ ΤΟΥ CMV ΣΤΟ ΙΔΙΟ PEEP .ΜΕ ΒΑΣΗ ΤΗ ΣΥΓΚΕΚΡΙΜΕΝΗ ΠΕΙΡΑΜΑΤΙΚΗ ΔΙΑΤΑΞΗ ,  ΑΠΟ ΤΗΝ ΑΝΑΛΥΣΗΚΑΙ ΤΗΝ ΑΞΙΟΛΟΓΗΣΗ ΤΩΝ ΑΠΟΤΕΛΕΣΜΑΤΩΝ , ΒΓΑΙΝΟΥΝ ΤΑ ΠΑΡΑΚΑΤΩ   ΣΥΜΠΕΡΑΣΜΑΤΑ : ΟΑΕΡΙΣΜΟΣ ΥΨΗΛΗΣ ΣΥΧΝΟΤΗΤΑΣ ΜΕ ΕΚΤΟΞΕΥΣΗ ΣΕ ΣΥΓΚΡΙΣΗ ΜΕ ΤΟΝ   ΣΥΜΒΑΤ  ΙΚΟ ΜΗΧΑΝΙΚΟ ΑΕΡΙΣΜΟ ΕΠΙΔΕΙΝΩΝΕΙ ΤΟΝ ΔΕΙΚΤΗ ΟΞΥΓΟΝΩΣΗΣ ΣΤΗΝ</dc:description><dc:description xmlns:lang="en">THE PURPOSE OF OUR STUDY WAS THE COMPARISON BETWEEN THE CONVENTIONAL   MECHANICAL VENTILATION (CMV) AND THE HIGH FREQUENCY JET VENTILATION (HFJV) ,  REGARDINGTHE HEMODYNAMIC AND RESPIRETORY PARAMETERS IN ACUTE HYPOXEMIC  RESPIRATORY FAILURE.THE EXPERIMENTAL   MODEL THAT WAS SELECTED  WAS THE NON CARDIOGENIC PULMONARY EODEMA INDUCED BY INFUSION OF OLEIC ACID IN THE   PULMONARY ARTERY OF 12 DOGS WITH BODY WEIGHT 12-18 KG .AFTER STABILIZATION  ON THE CONVENTIONAL MECHANICAL VENTILATION (CONSTANT FLOW, VOLUME CONTROL   VENTILATION) , THE BASIC HEMODYNAMIC AND RESPIRATORY PARAMETERS WERE   MEASURED AND FINALLY THE LUNG INJURY WAS INDUCED .AS SOON AS THE OXYGENATION  INDEX (PAO2/FIO2) FELL BELOW 150 , THE ACUTE LUNG INJURY INDUCED BY OLEIC   ACID WAS CONSIDERED ADEQUATE .THEN   THE CMV WAS ALTENATED , IN THE RANDOM   ORDER BY HFJV WITH RESPIRATORY RATES 60 ,120 AND 240 BREATHS /MIN ON PEEP    =0 (ZEEP) AND PEEP=10 CM H2O Q A PARTICULAR ATTENTION WAS PAID , SO THAT   PCO2 REMAINED BETWEEN 38 AND 42 MMHG DURING ALL THE STAGES OF THE EX    PERIMENT .THE MEASUREMENTS OF THE HEMODYNAMIC AND RESPIRATORY PARAMETERS   WERE REPEATED IN EACH STAGE .THE HEMODYNAMIC AND RESPIRATORY PARAMETERS   DURING THE VARIOUS RESPIRATORY RATES OF HFJV WERE COMPARED TO THOSE OF CMV   ON THE SAME PEEP .FROM THE STATISTI  CAL ANALYSIS AND EVALUATION OF COLECTED  AND CALCULATED DATA , THE FOLLOWING CONCLUSIONS WERE DRAWNQTHE HIGH  FREQUENCY JET VENTILATION COMPARED TO THE CONVENTIONAL MECHANICAL   VENTILATION (CMV) DERERIORATES THE OXYGANATION INDEX IN ACUTE HYPOXEMIC   RESPIRATI  ON FAILURE , SINCE IT REDUCES THE MAIN AIRWAY PRESSURE IN</dc:description><dc:title xmlns:lang="el">ΑΙΜΟΔΥΝΑΜΙΚΕΣ ΚΑΙ ΑΝΑΠΝΕΥΣΤΙΚΕΣ ΕΠΙΠΤΩΣΕΙΣ ΣΕ ΟΞΕΙΑ ΑΝΑΠΝΕΥΣΤΙΚΗ ΑΝΕ- ΠΑΡΚΕΙΑ:ΠΕΙΡΑΜΑΤΙΚΗ ΣΥΓΚΡΙΤΙΚΗ ΜΕΛΕΤΗ ΑΠΟ ΤΗΝ ΕΦΑΡΜΟΓΗ ΤΟΥ ΣΥΜΒΑΤ...</dc:title><dc:title xmlns:lang="en">HEMODYNAMIC AND RESPIRATORY CONSEQUENCES IN ACUTE RESPIRATORY FAILURE. EXPERIMENTAL COMPARATIVE STUDY IN THE APPLICATION OF THE CONVENTIONAL MECHANICAL VENTILATION AND THE HIGH FREQUENCY JET VENTILATION</dc:title><dc:creator xmlns:lang="el">Λαγονίδης, Δημήτριος</dc:creator><dc:date>1999</dc:date><dc:language>gre</dc:language><dc:subject xmlns:lang="en">ACUTE HYPOXEMIC RESPIRATORY FAILURE</dc:subject><dc:subject xmlns:lang="en">CONVENTIONAL MECHANICAL VENTILATION</dc:subject><dc:subject xmlns:lang="en">Experimental study</dc:subject><dc:subject xmlns:lang="en">Hemodynamic parameters</dc:subject><dc:subject xmlns:lang="en">High frequency jet ventilation</dc:subject><dc:subject xmlns:lang="en">RESPIRATORY PARAMETERS</dc:subject><dc:subject xmlns:lang="el">ΑΕΡΙΣΜΟΣ ΥΨΗΛΗΣ ΣΥΧΝΟΤΗΤΑΣ ΜΕ ΕΚΤΟΞΕΥΣΗ</dc:subject><dc:subject xmlns:lang="el">Αιμοδυναμικές παράμετροι</dc:subject><dc:subject xmlns:lang="el">Αναπνευστικές παράμετροι</dc:subject><dc:subject xmlns:lang="el">ΟΞΕΙΑ ΥΠΟΞΑΙΜΙΚΗ ΑΝΑΠΝΕΥΣΤΙΚΗ ΑΝΕΠΑΡΚΕΙΑ</dc:subject><dc:subject xmlns:lang="el">Πειραματική μελέτη</dc:subject><dc:subject xmlns:lang="el">ΣΥΜΒΑΤΙΚΟΣ ΜΗΧΑΝΙΚΟΣ ΑΕΡΙΣΜΟΣ</dc:subject><dc:publisher xmlns:lang="el">Αριστοτέλειο Πανεπιστήμιο Θεσσαλονίκης (ΑΠΘ)</dc:publisher><dc:publisher xmlns:lang="en">Aristotle University Of Thessaloniki (AUTH)</dc:publisher><dc:subject xmlns:lang="el">Ιατρική και Επιστήμες Υγείας</dc:subject><dc:subject xmlns:lang="en">Medical and Health Sciences</dc:subject><dc:subject xmlns:lang="el">Κλινική Ιατρική</dc:subject><dc:subject xmlns:lang="en">Clinical Medicine</dc:subject><dc:identifier>10.12681/eadd/10509</dc:identifier><dc:identifier>http://hdl.handle.net/10442/hedi/10509</dc:identifier><dc:type>PhD Thesis</dc:type></oai_dc:dc></metadata></record></GetRecord></OAI-PMH>